Anhui Shengshi 320t Glass Kiln Ceramic Filter | ZTW Tech

Search intent: case study (proven reference) | Anhui Shengshi New Material Technology Co., Ltd applied a ceramic catalytic filter line to a 320 t/day glass melting furnace in April 2021 and has run it under its own operating team ever since. This article sets out what the published project record actually contains, why a furnace of that size changes the selection criteria, and how the operating signals should be read. Measured values below belong to a filed typical application case for the same technology route and are labelled as a reference benchmark rather than as measurements from this plant.

1. What the project record shows

ZTW Tech publishes its project list as a page on this site, and that list is the authoritative record of customer names, project scope and operating dates. One entry belongs to this customer:

  • 320 t glass melting kiln flue gas ceramic catalytic tube desulfurization, denitrification and dust removal integrated project - April 2021
Project element Registered content
Owner Anhui Shengshi New Material Technology Co., Ltd
Industry New material production - 320 t/day glass melting furnace
Registered scope Ceramic catalytic tube desulfurization, denitrification and dust removal integrated
Commissioning April 2021
Operating record April 2021 to November 2026, about 5 years and 7 months
Operating model Owner-operated. The project list records third-party BOT operation for other owners, but no operating arrangement is registered for this line
Defluorination Not part of the registered scope here, unlike the glass container lines where defluorination is routinely specified

Two facts follow from the registered dates and scope. The line has run for more than five years, which places it beyond the usual first-replacement interval, and it is an owner-run installation, so reagent records, differential pressure trends and element inspection all sit inside the plant's own team rather than inside an operating contract.

2. Why a 320 t furnace changes the selection criteria

A furnace running 320 t of glass a day cannot stop for a filter change without a direct production loss, so the first question for a line of this size is not efficiency but isolability. The ceramic catalytic filter element is divided into chambers, so a single chamber can be isolated for regeneration or element replacement while the remaining chambers keep operating. For a 320 t furnace that is the difference between a planned maintenance window and an unplanned output loss.

Selection criterion Why it matters at 320 t/day
Chamber isolation One chamber isolated for regeneration or replacement while the rest stay in service
Element length The ultra-low-resistance ceramic fibre element runs at 80-150 Pa at 1 m/min; a 3 m element can replace a conventional 4 m or even 6 m element, so the retrofit space is in grade and chamber allocation rather than length
Structural strength C-ring strength above 0.4 MPa, relevant to repeated thermal cycling in a large furnace
Operating window DeNOx holds in the 220-400 °C band with peak efficiency at 280-400 °C, so the element temperature rating and the reaction temperature are two different numbers
Reagent metering Absorbent dosing has to be sized for the actual gas volume, otherwise cake formation and ammonia slip rise together

The product reference for the element used on this route is the CeraCAT denitrification ceramic catalytic filter page, and the reactor arrangement behind the scope is described on the integrated process page.

3. Measured performance for the same route, with its conditions

The measured figures below come from typical application case number 793 of the China Association of Environmental Protection Industry, covering the 15,000 m³/h glass melting furnace flue gas treatment project of Sichuan Yibin Universal Glass Manufacturing Co., Ltd. It entered service on 1 May 2017 and was accepted on 11 October 2017, with all indicators met or below the contractual targets, and the case content was confirmed by seal by both the owner and the applicant. These are same-route measured values, not measurements taken at the Anhui Shengshi line.

Indicator Inlet / condition Measured outlet Condition it depends on
NOx above 3,000 mg/m³ below 100 mg/m³ Denitrification holds while the gas stays above 280 °C, so no extra heating fuel is required
HF above 38 mg/m³ below 5 mg/m³ Fluoride originates in the glass batch, so the dry route needs an alkaline absorbent
SO₂ - below 5 mg/m³ Ca(OH)₂ dry desulfurization at 20 kg/h
Particulate matter - below 5 mg/m³ The element performs SCR denitrification and dust removal together
Ammonia slip - below 5 ppm 20% ammonia solution atomised; depends on nozzle and mixing
System pressure drop - below 3,500 Pa The equivalent conventional train on the same duty basis exceeds 4,500 Pa; power saving above 20%

The plant configuration behind that case is also public: 416 ceramic filter elements in a four-chamber arrangement, 1,306 m² of total filtration area, reactor design pressure below 2,500 Pa, total investment of 6 million CNY and annual operating cost of about 1.88 million CNY. The dry reagent reaction products - calcium sulphate, calcium fluoride and calcium chloride - are captured on the element surface and discharged with the ash, and at a glass furnace they can be returned to the batch as raw material, so the route produces no waste for disposal and no wastewater stream. Those figures describe one specific line and scale with gas volume, so they have to be recalculated for a different furnace size rather than copied.

4. How to read the operating signals

For an owner-run installation the operating record matters more than the installation photograph. Four signals separate a normal load change from a real problem.

Signal First check What it usually means
Differential pressure rising while outlet NOx stays normal Absorbent dosing rate and actual gas volume, derived from reagent consumption and flue gas CO₂ Dust loading or over-dosing, not catalyst decay
Outlet NOx rising while differential pressure stays normal Whether the flue gas temperature is still above 280 °C and whether catalyst activity is retained Reaction temperature out of the active band; check this before adding heating fuel
Desulfurizer consumption rising Sulfur, fluorine and chlorine content of the incoming batch A feed-side change rather than an equipment fault
Ammonia slip rising Nozzle atomisation and the static mixing section Over-spray or poor mixing; lowering the spray rate first would turn an ammonia problem into an NOx problem

5. Frequently Asked Questions

>What is the operating record of this installation?

The project list registers the ceramic catalytic tube desulfurization, denitrification and dust removal integrated project at the 320 t glass melting furnace in April 2021. Counting to November 2026, the line has run for about 5 years and 7 months. The list records names and dates only, so no performance figure for this plant is inferred from it.

>Can the furnace keep running during an element replacement?

Yes. The element is divided into chambers, so one chamber can be isolated for regeneration or replacement while the remaining chambers stay in service, which is the decisive advantage at 320 t/day. The replacement plan still has to be aligned with the furnace maintenance window.

>How long does the element last?

The product warranty is 5 years and the maximum usable life is 8 to 10 years, and the same-route filed case records catalyst life above 5 years. Actual life depends on heat release and on the dust load, so the replacement point should be decided from operating data rather than from a fixed date.

>How is this case different from the reference benchmark?

The measured figures belong to typical application case number 793 of the China Association of Environmental Protection Industry, covering the 15,000 m³/h glass melting furnace of Sichuan Yibin Universal Glass Manufacturing Co., Ltd, commissioned in May 2017 and accepted in October 2017 with confirmation by seal. They are quoted as a same-route benchmark, separate from the registered entry for Anhui Shengshi New Material Technology Co., Ltd.

>What should be requested before comparing proposals?

Three items: the commissioning and acceptance dates, the measured stack concentrations before and after treatment with the operating conditions attached, and the operating model under which the reference plant runs today. All three are on the public record through the 2018 national advanced pollution control technology catalogue, and a filter sample can also be tested against your own flue gas.

6. Technical basis

ZTW Tech's ceramic catalytic tube multi-pollutant coordinated control technology is listed in the 2018 National Catalogue of Advanced Pollution Prevention and Control Technologies (Air Pollution Control) issued by the Ministry of Ecology and Environment, and the ceramic catalytic integrated flue gas multi-pollutant coordinated control technology is listed in the 2020 National Catalogue of Major Environment Protection Technologies and Equipment for Encouraged Development issued jointly by the Ministry of Industry and Information Technology, the Ministry of Science and Technology and the Ministry of Ecology and Environment.